The FDA Guidance That Lets a Synthetic Peptide Copy an rDNA Drug
A synthetic peptide may copy a brand grown in cells, but a copy grown the brand's way may not, and that is the rule.

In May 2021 the FDA published a guidance titled “ANDAs for Certain Highly Purified Synthetic Peptide Drug Products That Refer to Listed Drugs of rDNA Origin,” and in July 2026 it withdrew it. In between, the guidance did one specific and slightly strange thing. It told generic companies that they could copy a peptide drug the brand makes in genetically engineered cells by building the same molecule through chemistry instead. They could then file an abbreviated new drug application, or ANDA, claiming the two are the same drug.
That is the basic ANDA peptide answer. A synthetic peptide can reference an rDNA-origin brand through the generic pathway if the applicant shows the active ingredient is the “same,” meaning matching structure and impurities no worse than the brand’s. The odd corollary is that a copy made the brand’s way, using recombinant DNA, does not qualify for the ANDA at all and has to go the full new drug application route. The 2021 guidance covered five products. It has since been replaced by product-specific guidances, including ones for GLP-1s.
What the 2021 guidance actually allowed
Here is the problem, stated with the gravity it deserves. A generic drug must be the same as the drug it copies. The drug it copies is made by living cells. The generic is made in a reactor by chemists. Living cells and chemists are not the same (the chemists will tell you this unprompted). The question presented is whether their output can be.
The FDA’s answer, which took a while, was yes, for a short list. It issued a draft in October 2017 to help applicants work out when a synthetic peptide referencing an approved rDNA-origin product belonged under section 505(j), the generic route, rather than section 505(b), the new drug route. According to Lachman Consultant Services, the FDA’s Office of Generic Drugs and Office of Pharmaceutical Quality concluded that “advances in analytical methods and the state of peptide synthesis and characterization had progressed sufficiently” to accept such ANDAs. The covered products were glucagon, liraglutide, nesiritide, teriparatide and teduglutide (five being the number you pick when you want to see what happens first). That’s it.
Liraglutide is the one that mattered for this site. A generic liraglutide got tentative approval as early as June 21, 2024, and Hikma received full approval and launched in December 2024. That was the first real precedent for a synthetic GLP-1 generic referencing an rDNA originator. (The fine print of how a reactor’s peptide gets to call itself a yeast-free twin of the cell’s peptide is the rest of this post.)
How the ANDA peptide sameness test works
In absurdly plain words: you build the molecule a different way, chop both versions into small pieces, weigh the pieces very precisely, and if every piece matches you say the molecules match. This is called demonstrating primary structure sameness, and the chopping-and-weighing is peptide mapping.
For instance, one published method used ultra-performance liquid chromatography with high-resolution mass spectrometry, cutting semaglutide and liraglutide with the enzymes Glu-C and chymotrypsin. It got full sequence coverage, with mass error below 10 ppm. Ten parts per million is a very small disagreement to tolerate between two things that are supposed to be identical.
The sequence is only the first layer. The sameness criteria call for the same primary, secondary and tertiary structure as the reference listed drug, so the chain has to fold the same way too. They also call for equal or lower levels of aggregates. Clumps are allowed. Not more clumps.
The impurity rules, which are the real test
Making the right molecule is the easy part, relatively speaking (relative to what, I could not tell you). The hard part is everything else in the vial. Peptides of up to 40 amino acids sit in an intermediate category between small-molecule drugs and large biologics, and the conventional impurity guidelines for small molecules do not fully cover their structural complexity or immunogenicity risk.
So the rules work a lot like returning a rental car. Any scratch already on the car when you picked it up is fine, as long as it hasn’t gotten bigger. Any new scratch has to be small and explained. Specifically, each peptide-related impurity found in both the generic and the brand must be at the same level or lower in the generic. A new specified impurity may not exceed 0.5 percent of the drug substance, and even below that it must be characterized and justified as not affecting safety or effectiveness. Impurities at 0.10 percent or higher need structural identification. The reason is not fussiness: new impurities can introduce T-cell epitopes and trigger unwanted immune responses, which is why sponsors are asked about any impurity the brand doesn’t have.
Then there are batches. The guidance does not settle the number. According to ELIQUENT, it says only that “a statistically valid number” should be evaluated, and the common practice is at least three batches each of the generic and the reference drug, with the generic’s three made from at least two different batches of drug substance. Getting representative batches of the brand is, in ELIQUENT’s words, “crucial and often rate-limiting.”
Think about that for a second. The rate-limiting step in copying a drug is buying the drug. I assume the brand companies are doing everything they can to help. A regulatory affairs manager somewhere is on the phone saying “hi, it’s us again, could we get three more lots, ideally with different expiry dates,” and that is a real part of the job.
What replaced the guidance in 2026
According to Spakinect, the FDA withdrew the May 2021 guidance in July 2026 and on July 28, 2026 published 17 revised draft product-specific guidances for peptide products, the documents the agency uses to give drug-by-drug recommendations for ANDAs. The revision appeared on the Center for Drug Evaluation and Research’s 2026 Guidance Agenda, and the action aligns with the FDA’s Drug Competition Action Plan. RAPS reported on October 30, 2026 on FDA guidance spelling out acceptance criteria for synthetic peptide ANDAs.
So one general document became seventeen specific ones (a ratio that regulatory consultants can only admire). To be fair, that is how you’d expect a regulator to handle molecules that each fold their own way. Exactly which impurity thresholds and analytical methods each new draft sets for each GLP-1 is not settled in any single public statement, and since these are drafts, it may stay unsettled for a while. (I write about regulatory titles for a living and have read this one aloud several times. It does not get shorter.)
Three ways to read the recombinant exclusion
The strangest rule in all this stuff is the one where a recombinant copy can’t be a generic of a recombinant brand, but a synthetic copy can. There are, roughly, three ways to read this.
The first is analytical. Chemistry leaves chemistry-shaped impurities, which you can list, weigh and compare against the brand line by line. Cells leave cell-shaped ones. An FDA workshop with the Center for Research on Complex Generics in September 2025 addressed recombinant host-cell impurity control as its own topic, separate from sameness. On this reading the line falls where the agency can check the work with a mass spectrometer, and it’s fine.
The second is institutional. The ANDA is a pathway for things that can be proven identical, and the FDA only agreed that peptides qualified once its offices decided the analytics had caught up. It then limited that to five products and later went product by product. On this reading the exclusion isn’t a judgment about recombinant manufacturing. It’s just the edge of what the agency has signed off on so far.
The third is the least comfortable. Under this system, “same” means same molecule, same folding, no new impurity above 0.5 percent, no shared impurity higher than the brand’s, no more aggregates, all measured against brand batches the generic company has to go buy. The point is that the copy has to be at least as clean as the original on every axis the original sets, while also being made a different way. The one method you may not use to make a generic is the method that made the drug.
Which means that a company manufacturing the reference product exactly as the brand does, in the same cells, could not file an ANDA for it, and that includes, in principle, the brand.
Sources
- Synthetic Peptide Products Eligible for ANDA Submission – Maybe! - Lachman Consultant Services, Inc.
- FDA Updates 17 Draft Guidances for Generic GLP-1 and Other Peptide Drug Development | Spakinect
- Draft Product-Specific Guidances for Certain Generic ...
- ANDAs for certain highly purified synthetic peptide drug ...
- Analytical considerations for characterization of generic peptide product: A regulatory insight
- FDA Requirements for Generic GLP-1 Peptide Injections - ELIQUENT
- FDA guidance spells out acceptance criteria for synthetic peptide ANDAs | RAPS
- Peptide mapping analysis of synthetic semaglutide and liraglutide for generic development of drugs originating from recombinant DNA technology
- Peptide mapping analysis of synthetic semaglutide and liraglutide for generic development of drugs originating from recombinant DNA technology.
- Peptide mapping analysis of synthetic semaglutide and ...
- Immunogenicity risk assessment of synthetic peptide drugs and their impurities.
- Assessment of innate immune response modulating impurities (IIRMI) in synthetic peptide drugs (liraglutide)
- Hikma receives FDA approval and launches the generic version of Victoza®, Liraglutide, in the US | Hikma
- FDA Approves First Generic of Once-Daily GLP-1 Injection ...
- Navigating the GLP-1 Generic Drug Pathway - The Center for Research on Complex Generics (CRCG)
- Peptide-Related Impurities and Degradation
GLP Generics explains published research, guidance and filings. It is not regulatory, legal or medical advice, and it never recommends a supplier, a product or a dose.